2 way control module wireless relay¶
This documentation was generated from: xiaomi_lumi.relay.c2acn01.json
| Attribute | Value |
|---|---|
| status | Silver |
| product | 2 way control module wireless relay |
| modelid | lumi.relay.c2acn01 |
| manufacturername | LUMI |
1. On/Off output¶
Endpoint: /lights
Top level attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| lastannounced | ISO 8601 timestamp | Timestamp of the last power-cyle or rejoin. | R |
| lastseen | ISO 8601 timestamp | Timestamp of the last communication. | R |
| manufacturername | String | "LUMI" | R |
| modelid | String | "lumi.relay.c2acn01" | R |
| name | String | Name of the resource. | RW |
| swversion | String | Firmware version of the device. | R |
| type | String | "On/Off output" | R |
| uniqueid | String | Unique identifier of the resource. | R |
| swversion | String | Firmware version of the device. | R |
| type | String | "On/Off output" | R |
| uniqueid | String | Unique identifier of the resource. | R |
State attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| alert | String | The currently active alert effect. Default: none
|
RW |
| on | Bool | True when device is on; false when off. | RW |
| reachable | Bool | When true the device is assumed to be operational. | R |
2. On/Off output¶
Endpoint: /lights
Top level attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| lastannounced | ISO 8601 timestamp | Timestamp of the last power-cyle or rejoin. | R |
| lastseen | ISO 8601 timestamp | Timestamp of the last communication. | R |
| manufacturername | String | "LUMI" | R |
| modelid | String | "lumi.relay.c2acn01" | R |
| name | String | Name of the resource. | RW |
| swversion | String | Firmware version of the device. | R |
| type | String | "On/Off output" | R |
| uniqueid | String | Unique identifier of the resource. | R |
| swversion | String | Firmware version of the device. | R |
| type | String | "On/Off output" | R |
| uniqueid | String | Unique identifier of the resource. | R |
State attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| alert | String | The currently active alert effect. Default: none
|
RW |
| on | Bool | True when device is on; false when off. | RW |
| reachable | Bool | When true the device is assumed to be operational. | R |
3. ZHAPower¶
Endpoint: /sensors
Top level attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| lastannounced | ISO 8601 timestamp | Timestamp of the last power-cyle or rejoin. | R |
| lastseen | ISO 8601 timestamp | Timestamp of the last communication. | R |
| manufacturername | String | "LUMI" | R |
| modelid | String | "lumi.relay.c2acn01" | R |
| name | String | Name of the resource. | RW |
| swversion | String | Firmware version of the device. | R |
| type | String | "ZHAPower" | R |
| uniqueid | String | Unique identifier of the resource. | R |
| swversion | String | Firmware version of the device. | R |
| type | String | "ZHAPower" | R |
| uniqueid | String | Unique identifier of the resource. | R |
Config attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| on | Bool | When true the sensor is enabled in rules. Default: true |
RW |
| reachable | Bool | When true the device is assumed to be operational. | R |
| temperature | UInt8 | The current device temperature in °C. | R |
State attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| current | UInt16 | The measured current (in mA). Default: 0 |
RW |
| lastupdated | ISO 8601 timestamp | Timestamp when state was last updated. | R |
| power | Int16 | The measured power (in W). Default: 0 |
RW |
| voltage | UInt16 | The measured voltage (in V). Default: 0 |
RW |
4. ZHAConsumption¶
Endpoint: /sensors
Top level attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| lastannounced | ISO 8601 timestamp | Timestamp of the last power-cyle or rejoin. | R |
| lastseen | ISO 8601 timestamp | Timestamp of the last communication. | R |
| manufacturername | String | "LUMI" | R |
| modelid | String | "lumi.relay.c2acn01" | R |
| name | String | Name of the resource. | RW |
| swversion | String | Firmware version of the device. | R |
| type | String | "ZHAConsumption" | R |
| uniqueid | String | Unique identifier of the resource. | R |
| swversion | String | Firmware version of the device. | R |
| type | String | "ZHAConsumption" | R |
| uniqueid | String | Unique identifier of the resource. | R |
Config attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| on | Bool | When true the sensor is enabled in rules. Default: true |
RW |
| reachable | Bool | When true the device is assumed to be operational. | R |
| temperature | UInt8 | The current device temperature in °C. | R |
State attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| consumption | UInt64 | The measured consumption (in Wh). Default: 0 |
RW |
| lastupdated | ISO 8601 timestamp | Timestamp when state was last updated. | R |