Wiser Odace roller shutter switch (S520567W)

This documentation was generated from: wall_switch_shutter.json

AttributeValue
status Gold
product Wiser Odace roller shutter switch (S520567W)
modelid NHPB/SHUTTER/1
manufacturername Schneider Electric

1. Window covering device

Endpoint: /lights

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "Schneider Electric" R
modelid String "NHPB/SHUTTER/1" R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "Window covering device" R
uniqueid String Unique identifier of the resource. R

State attributes

AttributeDatatypeDescriptionAccess
lift UInt8 The lift state of a roller blind.

Default: 0

RW
open Bool True when open is detected. R
reachable Bool When true the device is assumed to be operational. R

2. ZHASwitch

Endpoint: /sensors

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "Schneider Electric" R
modelid String "NHPB/SHUTTER/1" R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "ZHASwitch" R
uniqueid String Unique identifier of the resource. R

Config attributes

AttributeDatatypeDescriptionAccess
duration UInt16 The duration in second to open or close the shutter.

Default: 120

RW
ledindication Bool Activates the LED indicator.

Default: false

RW
mode String The mode of the device, can be 'lift', 'lift&tilt' or null.

Default: lift&tilt

RW
locked Bool Locks or unlocks the device. This item has to be understood as child-lock.

Default: false

RW
on Bool When true the sensor is enabled in rules.

Default: true

RW
reachable Bool When true the device is assumed to be operational. R

State attributes

AttributeDatatypeDescriptionAccess
buttonevent UInt32 The last received button event. R
lastupdated ISO 8601 timestamp Timestamp when state was last updated. R