Thermostat TRV (TS0601)

This documentation was generated from: _TZE200_TS0601_trv.json

AttributeValue
status Gold
product Thermostat TRV (TS0601)
modelid TS0601
TS0601
TS0601
TS0601
TS0601
manufacturername _TZE200_bvu2wnxz
_TZE200_6rdj8dzm
_TZE200_gd4rvykv
_TZE200_rxntag7i
_TZE200_p3dbf6qs

1. ZHAThermostat

Endpoint: /sensors

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "_TZE200_bvu2wnxz"
"_TZE200_6rdj8dzm"
"_TZE200_gd4rvykv"
"_TZE200_rxntag7i"
"_TZE200_p3dbf6qs"
R
modelid String "TS0601"
"TS0601"
"TS0601"
"TS0601"
"TS0601"
R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "ZHAThermostat" R
uniqueid String Unique identifier of the resource. R

Config attributes

AttributeDatatypeDescriptionAccess
heatsetpoint Int16 Target temperature of a thermostat.

Default: 0

RW
offset Int16 Relative offset to the main measured value.

Default: 0

RW
locked Bool Locks or unlocks the device. This item has to be understood as child-lock.

Default: false

RW
on Bool When true the sensor is enabled in rules.

Default: true

RW
reachable Bool When true the device is assumed to be operational. R
mode String Mode of the device.
  • auto — 0
  • heat — 1
  • off — 2
RW

State attributes

AttributeDatatypeDescriptionAccess
lowbattery Bool True when the device battery runs low. R
lastupdated ISO 8601 timestamp Timestamp when state was last updated. R
temperature Int16 The current temperature in °C × 100.

Default: 0