Smart thermostat for electric heating (TH1123ZB/TH1124ZB)¶
This documentation was generated from: th1124zb.json
Attribute | Value |
---|---|
status | Gold |
product | Smart thermostat for electric heating (TH1123ZB/TH1124ZB) |
modelid | TH1123ZB TH1124ZB |
manufacturername | Sinope Technologies Sinope Technologies |
1. ZHAThermostat¶
Endpoint: /sensors
Top level attributes¶
Attribute | Datatype | Description | Access |
---|---|---|---|
id | String | Identifier of the resource, unique within an endpoint. | R |
lastannounced | ISO 8601 timestamp | Timestamp of the last power-cyle or rejoin. | R |
lastseen | ISO 8601 timestamp | Timestamp of the last communication. | R |
manufacturername | String | "Sinope Technologies" "Sinope Technologies" |
R |
modelid | String | "TH1123ZB" "TH1124ZB" |
R |
name | String | Name of the resource. | RW |
swversion | String | Firmware version of the device. | R |
type | String | "ZHAThermostat" | R |
uniqueid | String | Unique identifier of the resource. | R |
Config attributes¶
Attribute | Datatype | Description | Access |
---|---|---|---|
heatsetpoint | Int16 | Target temperature of a thermostat. Default: 0 |
RW |
resetpresence | Bool | Use it to address Occupancy specific attribute.
false = Unoccupied
true = Occupied Default: true |
RW |
mode | String | Mode of the device. | RW |
offset | Int16 | Relative offset to the main measured value. Default: 0 |
RW |
on | Bool | When true the sensor is enabled in rules. Default: true |
RW |
reachable | Bool | When true the device is assumed to be operational. | R |
schedule | String | On-device heating schedules. | RW |
schedule_on | Bool | Determines if on-device schedules for setting the heatsetpoint are currently used or if the thermostat is operated manually. Default: false |
RW |
unoccupiedheatsetpoint | Int16 | Target temperature of a thermostat when local is unoccupied. Default: 1800 |
RW |
externalsensortemp | Int16 | External sensor temperature used as Outdoor temperature on display. Default: -32768 |
RW |
ledindication | Bool | Use it for Backlight configuration.
false = On demand
true = Always ON Default: true |
RW |
unoccupiedheatsetpoint | Int16 | Target temperature of a thermostat when local is unoccupied. Default: 17 |
RW |
State attributes¶
Attribute | Datatype | Description | Access |
---|---|---|---|
lastupdated | ISO 8601 timestamp | Timestamp when state was last updated. | R |
on | Bool | True when device is on; false when off. | RW |
temperature | Int16 | The current temperature in °C × 100. Default: 0 |
R |
valve | UInt8 | The open percentage of the thermostat valve. Default: 0 |
R |
2. ZHAPower¶
Endpoint: /sensors
Top level attributes¶
Attribute | Datatype | Description | Access |
---|---|---|---|
id | String | Identifier of the resource, unique within an endpoint. | R |
lastannounced | ISO 8601 timestamp | Timestamp of the last power-cyle or rejoin. | R |
lastseen | ISO 8601 timestamp | Timestamp of the last communication. | R |
manufacturername | String | "Sinope Technologies" "Sinope Technologies" |
R |
modelid | String | "TH1123ZB" "TH1124ZB" |
R |
name | String | Name of the resource. | RW |
swversion | String | Firmware version of the device. | R |
type | String | "ZHAPower" | R |
uniqueid | String | Unique identifier of the resource. | R |
Config attributes¶
Attribute | Datatype | Description | Access |
---|---|---|---|
on | Bool | When true the sensor is enabled in rules. Default: true |
RW |
reachable | Bool | When true the device is assumed to be operational. | R |
State attributes¶
Attribute | Datatype | Description | Access |
---|---|---|---|
current | UInt16 | The measured current (in mA). Default: 0 |
RW |
lastupdated | ISO 8601 timestamp | Timestamp when state was last updated. | R |
power | Int16 | The measured power (in W). Default: 0 |
RW |
voltage | UInt16 | The measured voltage (in V). Default: 0 |
RW |
3. ZHAConsumption¶
Endpoint: /sensors
Top level attributes¶
Attribute | Datatype | Description | Access |
---|---|---|---|
id | String | Identifier of the resource, unique within an endpoint. | R |
lastannounced | ISO 8601 timestamp | Timestamp of the last power-cyle or rejoin. | R |
lastseen | ISO 8601 timestamp | Timestamp of the last communication. | R |
manufacturername | String | "Sinope Technologies" "Sinope Technologies" |
R |
modelid | String | "TH1123ZB" "TH1124ZB" |
R |
name | String | Name of the resource. | RW |
swversion | String | Firmware version of the device. | R |
type | String | "ZHAConsumption" | R |
uniqueid | String | Unique identifier of the resource. | R |
Config attributes¶
Attribute | Datatype | Description | Access |
---|---|---|---|
on | Bool | When true the sensor is enabled in rules. Default: true |
RW |
reachable | Bool | When true the device is assumed to be operational. | R |
State attributes¶
Attribute | Datatype | Description | Access |
---|---|---|---|
consumption | UInt64 | The measured consumption (in Wh). Default: 0 |
RW |
lastupdated | ISO 8601 timestamp | Timestamp when state was last updated. | R |
power | Int16 | The measured power (in W). Default: 0 |
RW |