AttributeValue
status Gold
product Smart thermostat for electric heating (TH1123ZB/TH1124ZB)
modelid TH1123ZB
TH1124ZB
manufacturername Sinope Technologies
Sinope Technologies

1. ZHAThermostat

Endpoint: /sensors

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "Sinope Technologies"
"Sinope Technologies"
R
modelid String "TH1123ZB"
"TH1124ZB"
R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "ZHAThermostat" R
uniqueid String Unique identifier of the resource. R

Config attributes

AttributeDatatypeDescriptionAccess
heatsetpoint Int16 Target temperature of a thermostat.

Default: 0

RW
resetpresence Bool Use it to address Occupancy specific attribute. false = Unoccupied true = Occupied

Default: true

RW
mode String Mode of the device. RW
offset Int16 Relative offset to the main measured value.

Default: 0

RW
on Bool When true the sensor is enabled in rules.

Default: true

RW
reachable Bool When true the device is assumed to be operational. R
schedule String On-device heating schedules. RW
schedule_on Bool Determines if on-device schedules for setting the heatsetpoint are currently used or if the thermostat is operated manually.

Default: false

RW
unoccupiedheatsetpoint Int16 Target temperature of a thermostat when local is unoccupied.

Default: 1800

RW
externalsensortemp Int16 External sensor temperature used as Outdoor temperature on display.

Default: -32768

RW
ledindication Bool Use it for Backlight configuration. false = On demand true = Always ON

Default: true

RW
unoccupiedheatsetpoint Int16 Target temperature of a thermostat when local is unoccupied.

Default: 17

RW

State attributes

AttributeDatatypeDescriptionAccess
lastupdated ISO 8601 timestamp Timestamp when state was last updated. R
on Bool True when device is on; false when off. RW
temperature Int16 The current temperature in °C × 100.

Default: 0

R
valve UInt8 The open percentage of the thermostat valve.

Default: 0

R

2. ZHAPower

Endpoint: /sensors

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "Sinope Technologies"
"Sinope Technologies"
R
modelid String "TH1123ZB"
"TH1124ZB"
R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "ZHAPower" R
uniqueid String Unique identifier of the resource. R

Config attributes

AttributeDatatypeDescriptionAccess
on Bool When true the sensor is enabled in rules.

Default: true

RW
reachable Bool When true the device is assumed to be operational. R

State attributes

AttributeDatatypeDescriptionAccess
current UInt16 The measured current (in mA).

Default: 0

RW
lastupdated ISO 8601 timestamp Timestamp when state was last updated. R
power Int16 The measured power (in W).

Default: 0

RW
voltage UInt16 The measured voltage (in V).

Default: 0

RW

3. ZHAConsumption

Endpoint: /sensors

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "Sinope Technologies"
"Sinope Technologies"
R
modelid String "TH1123ZB"
"TH1124ZB"
R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "ZHAConsumption" R
uniqueid String Unique identifier of the resource. R

Config attributes

AttributeDatatypeDescriptionAccess
on Bool When true the sensor is enabled in rules.

Default: true

RW
reachable Bool When true the device is assumed to be operational. R

State attributes

AttributeDatatypeDescriptionAccess
consumption UInt64 The measured consumption (in Wh).

Default: 0

RW
lastupdated ISO 8601 timestamp Timestamp when state was last updated. R
power Int16 The measured power (in W).

Default: 0

RW