Hue outdoor motion sensor (2022)

This documentation was generated from: sml004_motion_sensor.json

AttributeValue
status Gold
product Hue outdoor motion sensor (2022)
modelid SML004
SML004
manufacturername Philips
Signify Netherlands B.V.

1. ZHAPresence

Endpoint: /sensors

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "Philips"
"Signify Netherlands B.V."
R
modelid String "SML004"
"SML004"
R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "ZHAPresence" R
uniqueid String Unique identifier of the resource. R
productname String Product name of the device.

Default: Hue outdoor motion sensor

R
swversion String Firmware version of the device. R
type String "ZHAPresence" R
uniqueid String Unique identifier of the resource. R

Config attributes

AttributeDatatypeDescriptionAccess
alert String The currently active alert.

Default: none

  • "none" — no alert is set
  • "select" — device is identifying a short time
  • "lselect" — device is identifying a longer time
RW
battery UInt8 The current device battery level in 0–100 %.

Default: 0

R
delay UInt16 The occupied to unoccupied delay in seconds.

Default: 0

RW
ledindication Bool Activates the LED indicator.

Default: false

RW
on Bool When true the sensor is enabled in rules.

Default: true

RW
reachable Bool When true the device is assumed to be operational. R
sensitivity UInt8 The sensor sensitivity.

Default: 0

  • 0 — low
  • 1 — medium low
  • 2 — medium
  • 3 — medium high
  • 4 — high
RW
sensitivitymax UInt8 The maximum sensor sensitivity.

Default: 4

R
usertest Bool Activates the user test mode. RW

State attributes

AttributeDatatypeDescriptionAccess
lastupdated ISO 8601 timestamp Timestamp when state was last updated. R
presence Bool True when presence is detected.

Default: false

R

2. ZHALightLevel

Endpoint: /sensors

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "Philips"
"Signify Netherlands B.V."
R
modelid String "SML004"
"SML004"
R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "ZHALightLevel" R
uniqueid String Unique identifier of the resource. R
productname String Product name of the device.

Default: Hue outdoor light sensor

R
swversion String Firmware version of the device. R
type String "ZHALightLevel" R
uniqueid String Unique identifier of the resource. R

Config attributes

AttributeDatatypeDescriptionAccess
alert String The currently active alert.

Default: none

  • "none" — no alert is set
  • "select" — device is identifying a short time
  • "lselect" — device is identifying a longer time
RW
battery UInt8 The current device battery level in 0–100 %.

Default: 0

R
on Bool When true the sensor is enabled in rules.

Default: true

RW
reachable Bool When true the device is assumed to be operational. R
tholddark UInt16 Specifies at which lightlevel the dark attribute turns false.

Default: 12000

RW
tholdoffset UInt16 Relative offset to tholddark. Sets daylight attribute to true when when lightlevel is at or above (tholddark + tholdoffset).

Default: 7000

RW

State attributes

AttributeDatatypeDescriptionAccess
dark Bool True when lightlevel is lower than tholddark.

Default: false

R
daylight Bool True when lightlevel suits daylight according tholddark and tholdoffset configuration.

Default: false

R
lastupdated ISO 8601 timestamp Timestamp when state was last updated. R
lightlevel UInt16 The current Light level in 10000 log10 (lux) + 1.

Default: 0

R
lux UInt32 The current Light level in lux.

Default: 0

R

3. ZHATemperature

Endpoint: /sensors

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "Philips"
"Signify Netherlands B.V."
R
modelid String "SML004"
"SML004"
R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "ZHATemperature" R
uniqueid String Unique identifier of the resource. R
productname String Product name of the device.

Default: Hue outdoor temp. sensor

R
swversion String Firmware version of the device. R
type String "ZHATemperature" R
uniqueid String Unique identifier of the resource. R

Config attributes

AttributeDatatypeDescriptionAccess
alert String The currently active alert.

Default: none

  • "none" — no alert is set
  • "select" — device is identifying a short time
  • "lselect" — device is identifying a longer time
RW
battery UInt8 The current device battery level in 0–100 %.

Default: 0

R
offset Int16 Relative offset to the main measured value.

Default: 0

RW
on Bool When true the sensor is enabled in rules.

Default: true

RW
reachable Bool When true the device is assumed to be operational. R

State attributes

AttributeDatatypeDescriptionAccess
lastupdated ISO 8601 timestamp Timestamp when state was last updated. R
measured_value Double Represents the concentration as a fraction of 1.

Default: 0

R
temperature Int16 The current temperature in °C × 100.

Default: 0

R