Hue tap dial switch¶
This documentation was generated from: rdm002_tap_dial_switch.json
| Attribute | Value |
|---|---|
| status | Gold |
| product | Hue tap dial switch |
| modelid | RDM002 RDM002 |
| manufacturername | Philips Signify Netherlands B.V. |
1. ZHASwitch¶
Endpoint: /sensors
Top level attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| lastannounced | ISO 8601 timestamp | Timestamp of the last power-cyle or rejoin. | R |
| lastseen | ISO 8601 timestamp | Timestamp of the last communication. | R |
| manufacturername | String | "Philips" "Signify Netherlands B.V." |
R |
| modelid | String | "RDM002" "RDM002" |
R |
| name | String | Name of the resource. | RW |
| swversion | String | Firmware version of the device. | R |
| type | String | "ZHASwitch" | R |
| uniqueid | String | Unique identifier of the resource. | R |
| productname | String | Product name of the device. Default: Hue tap dial switch |
R |
| swversion | String | Firmware version of the device. | R |
| type | String | "ZHASwitch" | R |
| uniqueid | String | Unique identifier of the resource. | R |
Config attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| battery | UInt8 | The current device battery level in 0–100 %. Default: 0 |
R |
| on | Bool | When true the sensor is enabled in rules. Default: true |
RW |
| reachable | Bool | When true the device is assumed to be operational. | R |
State attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| buttonevent | UInt32 | The last received button event. | R |
| eventduration | UInt32 | Determines how long an event lasted. | R |
| lastupdated | ISO 8601 timestamp | Timestamp when state was last updated. | R |
2. ZHARelativeRotary¶
Endpoint: /sensors
Top level attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| lastannounced | ISO 8601 timestamp | Timestamp of the last power-cyle or rejoin. | R |
| lastseen | ISO 8601 timestamp | Timestamp of the last communication. | R |
| manufacturername | String | "Philips" "Signify Netherlands B.V." |
R |
| modelid | String | "RDM002" "RDM002" |
R |
| name | String | Name of the resource. | RW |
| swversion | String | Firmware version of the device. | R |
| type | String | "ZHARelativeRotary" | R |
| uniqueid | String | Unique identifier of the resource. | R |
| productname | String | Product name of the device. Default: Hue tap dial switch |
R |
| swversion | String | Firmware version of the device. | R |
| type | String | "ZHARelativeRotary" | R |
| uniqueid | String | Unique identifier of the resource. | R |
Config attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| battery | UInt8 | The current device battery level in 0–100 %. Default: 0 |
R |
| on | Bool | When true the sensor is enabled in rules. Default: true |
RW |
| reachable | Bool | When true the device is assumed to be operational. | R |
State attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| expectedeventduration | UInt16 | The expected duration of the last received rotary event. | R |
| expectedrotation | Int16 | The expected rotation of the last received rotary event. | R |
| lastupdated | ISO 8601 timestamp | Timestamp when state was last updated. | R |