Hue wall switch module

This documentation was generated from: rdm001_wall_switch_module.json

AttributeValue
status Gold
product Hue wall switch module
modelid RDM001
RDM004
RDM001
RDM004
manufacturername Signify Netherlands B.V.
Signify Netherlands B.V.
Philips
Philips

1. ZHASwitch

Endpoint: /sensors

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "Signify Netherlands B.V."
"Signify Netherlands B.V."
"Philips"
"Philips"
R
modelid String "RDM001"
"RDM004"
"RDM001"
"RDM004"
R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "ZHASwitch" R
uniqueid String Unique identifier of the resource. R
productname String Product name of the device.

Default: Hue wall switch module

R
swversion String Firmware version of the device. R
type String "ZHASwitch" R
uniqueid String Unique identifier of the resource. R

Config attributes

AttributeDatatypeDescriptionAccess
battery UInt8 The current device battery level in 0–100 %.

Default: 0

R
devicemode String Mode of the Hue wall switch module with possible values 'singlerocker', 'singlepushbutton', 'dualrocker', 'dualpushbutton'. Xiaomi devices have possible values of 'compatibility' and 'zigbee', but DO NOT CHANGE UNLESS YOU KNOW EXACTLY, WHAT YOU'RE DOING

Default: singlerocker

  • singlerocker — 0
  • singlepushbutton — 1
  • dualrocker — 2
  • dualpushbutton — 3
RW
on Bool When true the sensor is enabled in rules.

Default: true

RW
reachable Bool When true the device is assumed to be operational. R

State attributes

AttributeDatatypeDescriptionAccess
buttonevent UInt32 The last received button event. R
eventduration UInt32 Determines how long an event lasted. R
lastupdated ISO 8601 timestamp Timestamp when state was last updated. R