SP 120 smart plug

This documentation was generated from: sp_120.json

AttributeValue
status Gold
product SP 120 smart plug
modelid SP 120
manufacturername innr

1. On/Off plug-in unit

Endpoint: /lights

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "innr" R
modelid String "SP 120" R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "On/Off plug-in unit" R
uniqueid String Unique identifier of the resource. R

State attributes

AttributeDatatypeDescriptionAccess
alert String The currently active alert effect.

Default: none

  • "none" — light is not performing an alert
  • "select" — light is blinking a short time
  • "lselect" — light is blinking a longer time
RW
on Bool True when device is on; false when off. RW
reachable Bool When true the device is assumed to be operational. R

2. ZHAConsumption

Endpoint: /sensors

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "innr" R
modelid String "SP 120" R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "ZHAConsumption" R
uniqueid String Unique identifier of the resource. R

Config attributes

AttributeDatatypeDescriptionAccess
on Bool When true the sensor is enabled in rules.

Default: true

RW
reachable Bool When true the device is assumed to be operational. R

State attributes

AttributeDatatypeDescriptionAccess
consumption UInt64 The measured consumption (in Wh).

Default: 0

RW
lastupdated ISO 8601 timestamp Timestamp when state was last updated. R

3. ZHAPower

Endpoint: /sensors

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "innr" R
modelid String "SP 120" R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "ZHAPower" R
uniqueid String Unique identifier of the resource. R

Config attributes

AttributeDatatypeDescriptionAccess
on Bool When true the sensor is enabled in rules.

Default: true

RW
reachable Bool When true the device is assumed to be operational. R

State attributes

AttributeDatatypeDescriptionAccess
current UInt16 The measured current (in mA).

Default: 0

RW
lastupdated ISO 8601 timestamp Timestamp when state was last updated. R
power Int16 The measured power (in W).

Default: 0

RW
voltage UInt16 The measured voltage (in V).

Default: 0

RW