STARKVIND Air purifier

This documentation was generated from: starkvind_air_purifier.json

AttributeValue
status Gold
product STARKVIND Air purifier
modelid STARKVIND Air purifier
STARKVIND Air purifier table
manufacturername IKEA of Sweden
IKEA of Sweden

1. ZHAAirPurifier

Endpoint: /sensors

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "IKEA of Sweden"
"IKEA of Sweden"
R
modelid String "STARKVIND Air purifier"
"STARKVIND Air purifier table"
R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "ZHAAirPurifier" R
uniqueid String Unique identifier of the resource. R
productid String Product identifier of the device. R
swversion String Firmware version of the device. R
type String "ZHAAirPurifier" R
uniqueid String Unique identifier of the resource. R

Config attributes

AttributeDatatypeDescriptionAccess
filterlifetime UInt32 Filter life time in minutes (default: 6 months). Set this to indicate that the filter has been replaced.

Default: 259200

RW
ledindication Bool Activates the LED indicator.

Default: true

RW
locked Bool Locks or unlocks the device. This item has to be understood as child-lock.

Default: false

RW
mode String Mode of the device.

Default: off

  • off — 0
  • auto — 1
  • speed_1 — 10
  • speed_2 — 20
  • speed_3 — 30
  • speed_4 — 40
  • speed_5 — 50
RW
on Bool When true the sensor is enabled in rules.

Default: true

RW
reachable Bool When true the device is assumed to be operational. R

State attributes

AttributeDatatypeDescriptionAccess
deviceruntime UInt32 Device run time in minutes.

Default: 0

R
filterruntime UInt32 Filter run time in minutes.

Default: 0

R
lastupdated ISO 8601 timestamp Timestamp when state was last updated. R
replacefilter Bool True when device filter needs to be replaced.

Default: false

R
speed UInt8 The fan speed for mains powered devices.

Default: 0

R

2. ZHAParticulateMatter

Endpoint: /sensors

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "IKEA of Sweden"
"IKEA of Sweden"
R
modelid String "STARKVIND Air purifier"
"STARKVIND Air purifier table"
R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "ZHAParticulateMatter" R
uniqueid String Unique identifier of the resource. R
manufacturername String "IKEA of Sweden"
"IKEA of Sweden"
R
modelid String "STARKVIND Air purifier"
"STARKVIND Air purifier table"
R
name String Name of the resource. RW
productid String Product identifier of the device. R
swversion String Firmware version of the device. R
type String "ZHAParticulateMatter" R
uniqueid String Unique identifier of the resource. R

Config attributes

AttributeDatatypeDescriptionAccess
on Bool When true the sensor is enabled in rules.

Default: true

RW
reachable Bool When true the device is assumed to be operational. R

State attributes

AttributeDatatypeDescriptionAccess
lastupdated ISO 8601 timestamp Timestamp when state was last updated. R
measured_value Double Represents the concentration as a fraction of 1.

Default: 0

R
pm2_5 UInt16 Measured PM2.5 density in µg/m³. deprecated

Default: 0

R
airquality String Text representation of the air quality based on tVOC level. R