Air quality monitor (HS3AQ)

This documentation was generated from: HS3AQ_air_quality_sensor.json

AttributeValue
status Gold
product Air quality monitor (HS3AQ)
modelid HS3AQ-EFA-3.0
manufacturername HEIMAN

1. ZHATemperature

Endpoint: /sensors

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "HEIMAN" R
modelid String "HS3AQ-EFA-3.0" R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "ZHATemperature" R
uniqueid String Unique identifier of the resource. R

Config attributes

AttributeDatatypeDescriptionAccess
battery UInt8 The current device battery level in 0–100 %.

Default: 0

R
offset Int16 Relative offset to the main measured value.

Default: 0

RW
on Bool When true the sensor is enabled in rules.

Default: true

RW
reachable Bool When true the device is assumed to be operational. R

State attributes

AttributeDatatypeDescriptionAccess
lastupdated ISO 8601 timestamp Timestamp when state was last updated. R
temperature Int16 The current temperature in °C × 100.

Default: 0

R

2. ZHAHumidity

Endpoint: /sensors

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "HEIMAN" R
modelid String "HS3AQ-EFA-3.0" R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "ZHAHumidity" R
uniqueid String Unique identifier of the resource. R

Config attributes

AttributeDatatypeDescriptionAccess
battery UInt8 The current device battery level in 0–100 %.

Default: 0

R
offset Int16 Relative offset to the main measured value.

Default: 0

RW
on Bool When true the sensor is enabled in rules.

Default: true

RW
reachable Bool When true the device is assumed to be operational. R

State attributes

AttributeDatatypeDescriptionAccess
humidity UInt16 The current relative humidity in percent.

Default: 0

R
lastupdated ISO 8601 timestamp Timestamp when state was last updated. R

3. ZHAAirQuality

Endpoint: /sensors

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "HEIMAN" R
modelid String "HS3AQ-EFA-3.0" R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "ZHAAirQuality" R
uniqueid String Unique identifier of the resource. R

Config attributes

AttributeDatatypeDescriptionAccess
battery UInt8 The current device battery level in 0–100 %.

Default: 0

R
offset Int16 Relative offset to the main measured value.

Default: 0

RW
on Bool When true the sensor is enabled in rules.

Default: true

RW
reachable Bool When true the device is assumed to be operational. R

State attributes

AttributeDatatypeDescriptionAccess
airqualityppb UInt16 Measured tVOC level in ppb.

Default: 0

R
lastupdated ISO 8601 timestamp Timestamp when state was last updated. R