KEPZB-110 Keypad

This documentation was generated from: kepzb-110_keypad.json

AttributeValue
status Bronze
product KEPZB-110 Keypad
modelid KEPZB-110
KEPZB-110
manufacturername Develco Products A/S
frient A/S

1. ZHAAncillaryControl

Endpoint: /sensors

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "Develco Products A/S"
"frient A/S"
R
modelid String "KEPZB-110"
"KEPZB-110"
R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "ZHAAncillaryControl" R
uniqueid String Unique identifier of the resource. R

Config attributes

AttributeDatatypeDescriptionAccess
battery UInt8 The current device battery level in 0–100 %.

Default: 0

R
on Bool When true the sensor is enabled in rules.

Default: true

RW
pending Array Pending tasks to configure the device. R
reachable Bool When true the device is assumed to be operational. R

State attributes

AttributeDatatypeDescriptionAccess
action String The IAS arm action.

Default: disarmed

  • "disarmed" — disarmed not triggering alarm
  • "armed_stay" — trigger in stay mode
  • "armed_night" — trigger in night mode
  • "armed_away" — trigger in away mode
  • "invalid_code" — invalid code was entered
  • "not_ready" — alarm system not ready
  • "already_disarmed" — attempt to disarm was ignored
RW
lastupdated ISO 8601 timestamp Timestamp when state was last updated. R
lowbattery Bool True when the device battery runs low. R
seconds_remaining UInt32 The IAS panel seconds remaining.

Default: 0

RW
panel String The IAS panel.

Default: exit_delay

  • "disarmed" — disarmed not triggering alarm
  • "armed_stay" — trigger in stay mode
  • "armed_night" — trigger in night mode
  • "armed_away" — trigger in away mode
  • "exit_delay" — exit delay active
  • "entry_delay" — entry delay active
  • "not_ready" — alarm system not ready
  • "arming_stay" — arming stay mode
  • "arming_night" — arming night mode
  • "arming_away" — arming away mode
RW
tampered Bool True when the device tampered alarm was triggered. R

2. ZHAPresence

Endpoint: /sensors

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "Develco Products A/S"
"frient A/S"
R
modelid String "KEPZB-110"
"KEPZB-110"
R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "ZHAPresence" R
uniqueid String Unique identifier of the resource. R

Config attributes

AttributeDatatypeDescriptionAccess
duration UInt16 The duration until presence is automatically turned back to false. RW
on Bool When true the sensor is enabled in rules.

Default: true

RW
reachable Bool When true the device is assumed to be operational. R

State attributes

AttributeDatatypeDescriptionAccess
lastupdated ISO 8601 timestamp Timestamp when state was last updated. R
presence Bool True when presence is detected.

Default: false

R