Electricity meter interface 2 EMIZB-141

This documentation was generated from: emizb-141_electricity_meter_interface_2.json

AttributeValue
status Gold
product Electricity meter interface 2 EMIZB-141
modelid EMIZB-141
manufacturername frient A/S

1. ZHAConsumption

Endpoint: /sensors

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "frient A/S" R
modelid String "EMIZB-141" R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "ZHAConsumption" R
uniqueid String Unique identifier of the resource. R
swversion String Firmware version of the device. R
type String "ZHAConsumption" R
uniqueid String Unique identifier of the resource. R

Config attributes

AttributeDatatypeDescriptionAccess
battery UInt8 The current device battery level in 0–100 %.

Default: 0

R
interfacemode UInt8 Sets the protocol used for processing metering data.

Default: 0

  • 1 — Pulse counting electricity - Unit kWh
  • 2 — Pulse counting gas - Unit m3
  • 3 — Pulse counting water - Unit m3
  • 4 — Kamstrup KMP protocol
  • 5 — Linky protocol
  • 6 — DLMS-COSEM - IEC62056-21 mod A
  • 7 — P1 dutch standard – DSMR 2.3 version
  • 8 — P1 dutch standard – DSMR 4.0 version
RW
on Bool When true the sensor is enabled in rules.

Default: true

RW
pulseconfiguration UInt16 Pulse Configuration represents the number of pulses the meter outputs per unit.

Default: 0

RW
reachable Bool When true the device is assumed to be operational. R

State attributes

AttributeDatatypeDescriptionAccess
consumption UInt64 The measured consumption (in Wh).

Default: 0

RW
lastupdated ISO 8601 timestamp Timestamp when state was last updated. R
lowbattery Bool True when the device battery runs low. R
power Int16 The measured power (in W).

Default: 0

RW