1. ZHAThermostat¶
Endpoint: /sensors
Top level attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| lastannounced | ISO 8601 timestamp | Timestamp of the last power-cyle or rejoin. | R |
| lastseen | ISO 8601 timestamp | Timestamp of the last communication. | R |
| manufacturername | String | "Schneider Electric" | R |
| modelid | String | "EKO07259" | R |
| name | String | Name of the resource. | RW |
| swversion | String | Firmware version of the device. | R |
| type | String | "ZHAThermostat" | R |
| uniqueid | String | Unique identifier of the resource. | R |
Config attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| heatsetpoint | Int16 | Target temperature of a thermostat. Default: 0 |
RW |
| unoccupiedheatsetpoint | Int16 | Target temperature of a thermostat when local is unoccupied. Default: 1800 |
RW |
| mode | String | Mode of the device. | RW |
| offset | Int16 | Relative offset to the main measured value. Default: 0 |
RW |
| on | Bool | When true the sensor is enabled in rules. Default: true |
RW |
| reachable | Bool | When true the device is assumed to be operational. | R |
| locked | Bool | Locks or unlocks the device. This item has to be understood as child-lock. Default: false |
RW |
State attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| lastupdated | ISO 8601 timestamp | Timestamp when state was last updated. | R |
| on | Bool | True when device is on; false when off. | RW |
| temperature | Int16 | The current temperature in °C × 100. Default: 0 |
R |
2. ZHATemperature¶
Endpoint: /sensors
Top level attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| lastannounced | ISO 8601 timestamp | Timestamp of the last power-cyle or rejoin. | R |
| lastseen | ISO 8601 timestamp | Timestamp of the last communication. | R |
| manufacturername | String | "Schneider Electric" | R |
| modelid | String | "EKO07259" | R |
| name | String | Name of the resource. | RW |
| swversion | String | Firmware version of the device. | R |
| type | String | "ZHATemperature" | R |
| uniqueid | String | Unique identifier of the resource. | R |
Config attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| offset | Int16 | Relative offset to the main measured value. Default: 0 |
RW |
| on | Bool | When true the sensor is enabled in rules. Default: true |
RW |
| reachable | Bool | When true the device is assumed to be operational. | R |
State attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| lastupdated | ISO 8601 timestamp | Timestamp when state was last updated. | R |
| temperature | Int16 | The current temperature in °C × 100. Default: 0 |
R |
3. ZHATemperature¶
Endpoint: /sensors
Top level attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| lastannounced | ISO 8601 timestamp | Timestamp of the last power-cyle or rejoin. | R |
| lastseen | ISO 8601 timestamp | Timestamp of the last communication. | R |
| manufacturername | String | "Schneider Electric" | R |
| modelid | String | "EKO07259" | R |
| name | String | Name of the resource. | RW |
| swversion | String | Firmware version of the device. | R |
| type | String | "ZHATemperature" | R |
| uniqueid | String | Unique identifier of the resource. | R |
Config attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| offset | Int16 | Relative offset to the main measured value. Default: 0 |
RW |
| on | Bool | When true the sensor is enabled in rules. Default: true |
RW |
| reachable | Bool | When true the device is assumed to be operational. | R |
State attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| lastupdated | ISO 8601 timestamp | Timestamp when state was last updated. | R |
| temperature | Int16 | The current temperature in °C × 100. Default: 0 |
R |
4. ZHAConsumption¶
Endpoint: /sensors
Top level attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| lastannounced | ISO 8601 timestamp | Timestamp of the last power-cyle or rejoin. | R |
| lastseen | ISO 8601 timestamp | Timestamp of the last communication. | R |
| manufacturername | String | "Schneider Electric" | R |
| modelid | String | "EKO07259" | R |
| name | String | Name of the resource. | RW |
| swversion | String | Firmware version of the device. | R |
| type | String | "ZHAConsumption" | R |
| uniqueid | String | Unique identifier of the resource. | R |
Config attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| on | Bool | When true the sensor is enabled in rules. Default: true |
RW |
| reachable | Bool | When true the device is assumed to be operational. | R |
State attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| consumption | UInt64 | The measured consumption (in Wh). Default: 0 |
RW |