Intelligent heat alarm (HESZB-120)¶
This documentation was generated from: heszb-120_heat_detector.json
Attribute | Value |
---|---|
status | Gold |
product | Intelligent heat alarm (HESZB-120) |
modelid | HESZB-120 |
manufacturername | Develco Products A/S |
1. ZHAFire¶
Endpoint: /sensors
Top level attributes¶
Attribute | Datatype | Description | Access |
---|---|---|---|
id | String | Identifier of the resource, unique within an endpoint. | R |
lastannounced | ISO 8601 timestamp | Timestamp of the last power-cyle or rejoin. | R |
lastseen | ISO 8601 timestamp | Timestamp of the last communication. | R |
manufacturername | String | "Develco Products A/S" | R |
modelid | String | "HESZB-120" | R |
name | String | Name of the resource. | RW |
swversion | String | Firmware version of the device. | R |
type | String | "ZHAFire" | R |
uniqueid | String | Unique identifier of the resource. | R |
swversion | String | Firmware version of the device. | R |
type | String | "ZHAFire" | R |
uniqueid | String | Unique identifier of the resource. | R |
Config attributes¶
Attribute | Datatype | Description | Access |
---|---|---|---|
battery | UInt8 | The current device battery level in 0–100 %. Default: 0 |
R |
on | Bool | When true the sensor is enabled in rules. Default: true |
RW |
pending | Array | Pending tasks to configure the device. | R |
reachable | Bool | When true the device is assumed to be operational. | R |
State attributes¶
Attribute | Datatype | Description | Access |
---|---|---|---|
fire | Bool | True when fire is detected. | R |
lastupdated | ISO 8601 timestamp | Timestamp when state was last updated. | R |
lowbattery | Bool | True when the device battery runs low. | R |
test | Bool | True when a test is detected. Default: false |
R |
2. ZHATemperature¶
Endpoint: /sensors
Top level attributes¶
Attribute | Datatype | Description | Access |
---|---|---|---|
id | String | Identifier of the resource, unique within an endpoint. | R |
lastannounced | ISO 8601 timestamp | Timestamp of the last power-cyle or rejoin. | R |
lastseen | ISO 8601 timestamp | Timestamp of the last communication. | R |
manufacturername | String | "Develco Products A/S" | R |
modelid | String | "HESZB-120" | R |
name | String | Name of the resource. | RW |
swversion | String | Firmware version of the device. | R |
type | String | "ZHATemperature" | R |
uniqueid | String | Unique identifier of the resource. | R |
swversion | String | Firmware version of the device. | R |
type | String | "ZHATemperature" | R |
uniqueid | String | Unique identifier of the resource. | R |
Config attributes¶
Attribute | Datatype | Description | Access |
---|---|---|---|
battery | UInt8 | The current device battery level in 0–100 %. Default: 0 |
R |
offset | Int16 | Relative offset to the main measured value. Default: 0 |
RW |
on | Bool | When true the sensor is enabled in rules. Default: true |
RW |
reachable | Bool | When true the device is assumed to be operational. | R |
State attributes¶
Attribute | Datatype | Description | Access |
---|---|---|---|
lastupdated | ISO 8601 timestamp | Timestamp when state was last updated. | R |
temperature | Int16 | The current temperature in °C × 100. Default: 0 |
R |
3. Warning device¶
Endpoint: /lights
Top level attributes¶
Attribute | Datatype | Description | Access |
---|---|---|---|
id | String | Identifier of the resource, unique within an endpoint. | R |
lastannounced | ISO 8601 timestamp | Timestamp of the last power-cyle or rejoin. | R |
lastseen | ISO 8601 timestamp | Timestamp of the last communication. | R |
manufacturername | String | "Develco Products A/S" | R |
modelid | String | "HESZB-120" | R |
name | String | Name of the resource. | RW |
swversion | String | Firmware version of the device. | R |
type | String | "Warning device" | R |
uniqueid | String | Unique identifier of the resource. | R |
swversion | String | Firmware version of the device. | R |
type | String | "Warning device" | R |
uniqueid | String | Unique identifier of the resource. | R |
State attributes¶
Attribute | Datatype | Description | Access |
---|---|---|---|
alert | String | Start warning command payload has 5 Bytes. Byte 1: Options. 0x17 = Warning mode 1 (burglar), Strobe, Very high sound. Byte 2-3: Duration, Byte 4: Strobe duty cycle, Byte 5: Strobe level Default: none
|
RW |
reachable | Bool | When true the device is assumed to be operational. | R |