Electricity meter interface 2 EMIZB-141¶
This documentation was generated from: emizb-141_electricity_meter_interface_2.json
| Attribute | Value |
|---|---|
| status | Gold |
| product | Electricity meter interface 2 EMIZB-141 |
| modelid | EMIZB-141 |
| manufacturername | Develco Products A/S |
1. ZHAConsumption¶
Endpoint: /sensors
Top level attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| lastannounced | ISO 8601 timestamp | Timestamp of the last power-cyle or rejoin. | R |
| lastseen | ISO 8601 timestamp | Timestamp of the last communication. | R |
| manufacturername | String | "Develco Products A/S" | R |
| modelid | String | "EMIZB-141" | R |
| name | String | Name of the resource. | RW |
| swversion | String | Firmware version of the device. | R |
| type | String | "ZHAConsumption" | R |
| uniqueid | String | Unique identifier of the resource. | R |
| swversion | String | Firmware version of the device. | R |
| type | String | "ZHAConsumption" | R |
| uniqueid | String | Unique identifier of the resource. | R |
Config attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| battery | UInt8 | The current device battery level in 0–100 %. Default: 0 |
R |
| interfacemode | UInt8 | Sets the protocol used for processing metering data. Default: 0
|
RW |
| on | Bool | When true the sensor is enabled in rules. Default: true |
RW |
| pulseconfiguration | UInt16 | Pulse Configuration represents the number of pulses the meter outputs per unit. Default: 0 |
RW |
| reachable | Bool | When true the device is assumed to be operational. | R |
State attributes¶
| Attribute | Datatype | Description | Access |
|---|---|---|---|
| consumption | UInt64 | The measured consumption (in Wh). Default: 0 |
RW |
| lastupdated | ISO 8601 timestamp | Timestamp when state was last updated. | R |
| lowbattery | Bool | True when the device battery runs low. | R |
| power | Int16 | The measured power (in W). Default: 0 |
RW |