Ally thermostat

This documentation was generated from: etrv0100_thermostat.json

AttributeValue
status Gold
product Ally thermostat
modelid eTRV0100
eTRV0103
eT093WRO
eT093WRG
TRV001
manufacturername Danfoss
Danfoss
D5X84YU
D5X84YU
Danfoss

1. ZHAThermostat

Endpoint: /sensors

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "Danfoss"
"Danfoss"
"D5X84YU"
"D5X84YU"
"Danfoss"
R
modelid String "eTRV0100"
"eTRV0103"
"eT093WRO"
"eT093WRG"
"TRV001"
R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "ZHAThermostat" R
uniqueid String Unique identifier of the resource. R

Config attributes

AttributeDatatypeDescriptionAccess
battery UInt8 The current device battery level in 0–100 %.

Default: 0

R
displayflipped Bool Displayed content is normal or upside down.

Default: false

RW
externalsensortemp Int16 The temperature measured by an external sensor, can be used for regulation or displayed on screen.

Default: -8000

  • -8000 — Disabled
RW
externalwindowopen Bool The window state detected by an external sensor.

Default: false

RW
heatsetpoint Int16 Target temperature of a thermostat.

Default: 0

RW
loadbalancing Bool Thermostat runs stand alone (false) or shares load with others in the same room (true).

Default: false

RW
locked Bool Locks or unlocks the device. This item has to be understood as child-lock.

Default: false

RW
mode String Mode of the device.

Default: heat

RW
mountingmode Bool Determines if the device has entered the mounting state.

Default: false

RW
offset Int16 Relative offset to the main measured value.

Default: 0

RW
on Bool When true the sensor is enabled in rules.

Default: true

RW
radiatorcovered Bool Radiator is standing freely (false) or is covered (true). Set this to true for Danfoss Ally to use external temp sensor.

Default: false

RW
reachable Bool When true the device is assumed to be operational. R
schedule String On-device heating schedules. RW
schedule_on Bool Determines if on-device schedules for setting the heatsetpoint are currently used or if the thermostat is operated manually.

Default: false

RW
windowopendetectionenabled Bool Turns the window open detection feature on or off.

Default: true

RW

State attributes

AttributeDatatypeDescriptionAccess
errorcode String The error code given by the device. R
lastupdated ISO 8601 timestamp Timestamp when state was last updated. R
mountingmodeactive Bool The current mounting mode state.

Default: false

R
on Bool True when device is on; false when off. RW
temperature Int16 The current temperature in °C × 100.

Default: 0

R
valve UInt8 The open percentage of the thermostat valve.

Default: 0

R
windowopen String The current window state detected by the thermostat.

Default: Quarantine

  • "Quarantine" — Default
  • "Closed" — Window is closed
  • "Hold" — Window is maybe about to open
  • "Open" — Window is open
  • "Open (external), closed (internal)" — In window open state from external, but detected closed locally
R

2. ZHATime

Endpoint: /sensors

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "Danfoss"
"Danfoss"
"D5X84YU"
"D5X84YU"
"Danfoss"
R
modelid String "eTRV0100"
"eTRV0103"
"eT093WRO"
"eT093WRG"
"TRV001"
R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "ZHATime" R
uniqueid String Unique identifier of the resource. R

Config attributes

AttributeDatatypeDescriptionAccess
battery UInt8 The current device battery level in 0–100 %.

Default: 0

R
on Bool When true the sensor is enabled in rules.

Default: true

RW
reachable Bool When true the device is assumed to be operational. R

State attributes

AttributeDatatypeDescriptionAccess
lastset ISO 8601 timestamp Timestamp when the time attribute was last set on the device. R
lastupdated ISO 8601 timestamp Timestamp when state was last updated. R
localtime ISO 8601 timestamp The current local time set on the device. R
utc ISO 8601 timestamp Current timestamp in UTC set on the device. RW