Thermostat II BTH-RA

This documentation was generated from: thermostat2.json

AttributeValue
status Gold
product Thermostat II BTH-RA
modelid RBSH-TRV0-ZB-EU
manufacturername BOSCH

1. ZHAThermostat

Endpoint: /sensors

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "BOSCH" R
modelid String "RBSH-TRV0-ZB-EU" R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "ZHAThermostat" R
uniqueid String Unique identifier of the resource. R

Config attributes

AttributeDatatypeDescriptionAccess
battery UInt8 The current device battery level in 0–100 %.

Default: 0

R
displayflipped Bool Displayed content is normal or upside down.

Default: false

RW
externalsensortemp Int16 The temperature measured by an external sensor, can be used for regulation or displayed on screen.

Default: 0

RW
externalwindowopen Bool The window state detected by an external sensor.

Default: false

RW
heatsetpoint Int16 Target temperature of a thermostat.

Default: 0

RW
locked Bool Locks or unlocks the device. This item has to be understood as child-lock.

Default: false

RW
mode String Mode of the device.

Default: heat

RW
offset Int16 Relative offset to the main measured value.

Default: 0

RW
on Bool When true the sensor is enabled in rules.

Default: true

RW
reachable Bool When true the device is assumed to be operational. R
schedule String On-device heating schedules. RW
schedule_on Bool Determines if on-device schedules for setting the heatsetpoint are currently used or if the thermostat is operated manually.

Default: false

RW

State attributes

AttributeDatatypeDescriptionAccess
errorcode String The error code given by the device. R
lastupdated ISO 8601 timestamp Timestamp when state was last updated. R
on Bool True when device is on; false when off. RW
temperature Int16 The current temperature in °C × 100.

Default: 0

R
valve UInt8 The open percentage of the thermostat valve.

Default: 0

R