RADION TriTech ZB Wireless Motion Detector

This documentation was generated from: rfdl-zb-ms_motion_sensor.json

AttributeValue
status Gold
product RADION TriTech ZB Wireless Motion Detector
modelid RFDL-ZB-MS
manufacturername BOSCH

1. ZHAPresence

Endpoint: /sensors

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "BOSCH" R
modelid String "RFDL-ZB-MS" R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "ZHAPresence" R
uniqueid String Unique identifier of the resource. R
swversion String Firmware version of the device.

Default: none

R
type String "ZHAPresence" R
uniqueid String Unique identifier of the resource. R

Config attributes

AttributeDatatypeDescriptionAccess
battery UInt8 The current device battery level in 0–100 %.

Default: 0

R
on Bool When true the sensor is enabled in rules.

Default: true

RW
pending Array Pending tasks to configure the device. R
reachable Bool When true the device is assumed to be operational. R

State attributes

AttributeDatatypeDescriptionAccess
lastupdated ISO 8601 timestamp Timestamp when state was last updated. R
lowbattery Bool True when the device battery runs low. R
presence Bool True when presence is detected.

Default: false

R
tampered Bool True when the device tampered alarm was triggered. R

2. ZHALightLevel

Endpoint: /sensors

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "BOSCH" R
modelid String "RFDL-ZB-MS" R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "ZHALightLevel" R
uniqueid String Unique identifier of the resource. R
swversion String Firmware version of the device.

Default: none

R
type String "ZHALightLevel" R
uniqueid String Unique identifier of the resource. R

Config attributes

AttributeDatatypeDescriptionAccess
battery UInt8 The current device battery level in 0–100 %.

Default: 0

R
on Bool When true the sensor is enabled in rules.

Default: true

RW
reachable Bool When true the device is assumed to be operational. R
tholddark UInt16 Specifies at which lightlevel the dark attribute turns false.

Default: 12000

RW
tholdoffset UInt16 Relative offset to tholddark. Sets daylight attribute to true when when lightlevel is at or above (tholddark + tholdoffset).

Default: 7000

RW

State attributes

AttributeDatatypeDescriptionAccess
dark Bool True when lightlevel is lower than tholddark.

Default: false

R
daylight Bool True when lightlevel suits daylight according tholddark and tholdoffset configuration.

Default: false

R
lastupdated ISO 8601 timestamp Timestamp when state was last updated. R
lightlevel UInt16 The current Light level in 10000 log10 (lux) + 1.

Default: 0

R
lux UInt32 The current Light level in lux.

Default: 0

R

3. ZHATemperature

Endpoint: /sensors

Top level attributes

AttributeDatatypeDescriptionAccess
id String Identifier of the resource, unique within an endpoint. R
lastannounced ISO 8601 timestamp Timestamp of the last power-cyle or rejoin. R
lastseen ISO 8601 timestamp Timestamp of the last communication. R
manufacturername String "BOSCH" R
modelid String "RFDL-ZB-MS" R
name String Name of the resource. RW
swversion String Firmware version of the device. R
type String "ZHATemperature" R
uniqueid String Unique identifier of the resource. R
swversion String Firmware version of the device.

Default: none

R
type String "ZHATemperature" R
uniqueid String Unique identifier of the resource. R

Config attributes

AttributeDatatypeDescriptionAccess
battery UInt8 The current device battery level in 0–100 %.

Default: 0

R
offset Int16 Relative offset to the main measured value.

Default: 0

RW
on Bool When true the sensor is enabled in rules.

Default: true

RW
reachable Bool When true the device is assumed to be operational. R

State attributes

AttributeDatatypeDescriptionAccess
lastupdated ISO 8601 timestamp Timestamp when state was last updated. R
temperature Int16 The current temperature in °C × 100.

Default: 0

R